BLRVV - MONO-COAT, E179

  • MSDS: BLRVV
  • Manufacturer: CHEM TREND INC
  • Product Name: MONO-COAT, E179
  • National Stock Number: 6850-00N021181
Product Identification

Product ID:MONO-COAT, E179
MSDS Date:04/14/1989
FSC:6850
NIIN:00N021181
MSDS Number: BLRVV

Responsible Party
CHEM-TREND INC
1445 MCPHERSON PARK DR
HOWELL, MI 48844-0860
US

Emergency Phone: 517-546-4520

Info Phone: 517-546-4520

Cage: 2W738

Contractor
CHEM-TREND INC
860 HOWELL, MI 48844-0860 US

Telephone: 800-727-7730

Cage: 2W738

Ingredients

BENZIN; (NAPHTHA)

CAS: 8030-30-6

Fraction By Weight: 15-25%


1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: 45-55%

OSHA PEL 1000PPM/1250STEL

ACGIH TLV: 1000PPM/1250STEL9192


N-PROPYL ALCOHOL

CAS: 71-23-8

RTECS: UH8225000

Fraction By Weight: 20-30%

OSHA PEL 200 PPM/250 STEL

ACGIH TLV: S,200PPM/250STEL9192


DIPROPYLENE GLYCOL METHYL ETHER

CAS: 34590-94-8

RTECS: JM1575000

Fraction By Weight: 1.0%

OSHA PEL S,100PPM/150STEL

ACGIH TLV: S,100PPM/150STEL9192


RELEASE BLEND

Fraction By Weight: <5%


SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.,

RTECS: 9999999ZZ


SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY

RTECS: 9999999ZZ


A NIOSH/MSHA APPROVED AIR SUP RESP OR

RTECS: 9999999ZZ


ENVIRONMENTAL CONCENTRATIONS TO PERMISSIBLE EXPOSURE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: PRLNGD/RPTD CONT CAN DEFAT SKIN
WHICH MAY CAUSE IRRIT/DERM. AVOID SKIN CONT. EYE: LIQ PROD SPLASHED
IN EYE WILL PROBABLY IRRIT EYE. INHAL: VAP CONC ABOVE TLV MAY CAUSE
NASAL & RESP IRRIT, DIZZ, WEAK, FATIGUE, NAUS, & HDCH, AT VERY
HIGH LEVS, ANESTHESIA & ASPHYXIATION ARE POS. INGEST: ACUTE (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: ORAL TOXICITY OF SOLV MIX HAS NOT
BEEN MEASURED BUT IS ASSUMED TO BE LOW ON BASIS OF KNOWLEDGE OF
COMPONENTS. IF PROD IS ACCIDENTALLY SWALLOWED, DO NOT INDUCE VOMIT
BECAUSE OF DANGER OF ASPI R OF SOLV INTO LUNGS, WHICH CAN BE FATAL
DUE TO CHEM PNEUM. CHRONIC EFTS: IS LITTLE/NO EVIDENCE FOR ADVERSE
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:SKIN: WASH WITH SOAP AND WATER. LAUNDER CONTACTED CLOTHING
BEFORE REUSE. EYE: FLUSH WITH WATER FOR AT LEAST 15 MINUTES.
CONTACT PHYSICIAN. INHALATION: IF ADVERSE EFFECTS SUCH AS DIZZINESS
OR NAUSEA AR E NOTED, MOVE TO FRESH AIR. CONTACT PHYSICIAN.
INGESTION: DO NOT INDUCE VOMITING. CALL PHYSICIAN IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Lower Limits:SUPP DATA
Upper Limits:SUPP DATA
Extinguishing Media:USE FOAM, CARBON DIOXIDE OR DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:ACID FUMES MAY BE PRESENT FROM
DECOMPOSITION OF CHLORINATED SOLVENT DURING A FIRE. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:SMALL SPILLS:SOAK UP W/ABSORB MATL. LRG
SPILL:ELIMINATE ALL SOURCES OF IGNIT.VAPS ARE HVR THAN AIR & MAY
SPREAD LONG DISTANCES/COLLECT IN LOW SPOTS.DIKE AREA TO PVNT
RUNOFF, RECOVER LIQ, SOAK UP REMAI NING LIQ W/ABSORB MATL & SCRAPE
UP DRIED RESIDUE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:GROUND ALL EQUIP PUMPING PROD. PROTECT
FROM STATIC ELECTRICAL SPARKS OF OTHER IGNIT SOURCES. AVOID MIXING
W/WATER OF WATER-ALCOHOL MIX DURING HNDLG.
Other Precautions:STORE AWAY FROM STRONG OXIDIZERS. AVOID CONTACT WITH
WATER. NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL VICINITY OF
ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR UV RADIATION
MAY CAUSE FO RMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPRVD RESP MAY BE USED WHEN
ENGINEERING & WORK PRACT CNTRLS ARE NOT TECHNICALLY FEASIBLE, WHEN
SUCH CNTRLS ARE IN PROCESS OF BEING INSTALLED, OR WHEN THEY FALL &
NEED TO BE SUPPLEMENTED. I F USE OF RESP IS NEC, USE ONLY (ING 8)
Ventilation:GOOD INDUSTRIAL HYGIENE PRACT RECOM THAT ENGINEERING CNTRLS
(SUCH AS LOCAL &/OR MECH VENT) BE USED TO REDUCE (ING 9)
Protective Gloves:POLYVINYL ALCOHOL GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:APPROPRIATE CLOTHING TO AVOID SKIN CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
LEL: HYDROCARBON NAPHTHA-1.0%, N-PROPANOL- 1.5%. UEL: HYDROCARBON
NAPHTHA-6.0%, N-PROPANOL-13.5%. EFTS OF OVEREXP: EFTS OF OVEREXP:
EFTS ON HUMANS DUE TO LONG TERM EXPOS TO VAPS OF COMPONENT SOLV AT
T LV LEVS/BELOW. CHLOROCARBON MATLS HAVE PRDCED SENSIT OF
MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE (ING 6)

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:140F,60C
Vapor Pres:334
Vapor Density:>1
Spec Gravity:1.03
Evaporation Rate & Reference:<1
Solubility in Water:NIL
Appearance and Odor:CLEAR FLUID; ALCOHOL ODOR.
Percent Volatiles by Volume:>95

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:HYDROCARBON DECOMPOSITION PRODUCTS AT
ELEVATED TEMPERATURES. ACID FUMES DURING A FIRE. HCL, PHOSGENE

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.